    • NOTE: To avoid potential equipment damage, or liabilities associated with this installation, we recommend a request be made to Vaisala to supply the BT Module factory installed with a DB9F connector. Geotab does not recommend this interface installation be attempted in-field.

    • Bluetooth Module (BM10 enclosure)

  1. Brown wire connection from BT module goes to Pin 3 on  DB9 Green Wire from BT module goes to Pin 2 on DB9 Yellow Wire from BT module goes to Pin 5 on DB9
    • Brown wire connection from BT module goes to Pin 3 on DB9

    • Green Wire from BT module goes to Pin 2 on DB9

    • Yellow Wire from BT module goes to Pin 5 on DB9

  2. For IOX-WRKS Primary port integration (11500baud) , a DB9 female connection is required on the MD30: Use HRN-DB9SI15 if additional length is required.
    • For IOX-WRKS Primary port integration (11500baud) , a DB9 female connection is required on the MD30:

    • Use HRN-DB9SI15 if additional length is required.

  3. Use the secondary port “Only” If the primary port is occupied for spreader integration.
    • Use the secondary port “Only” If the primary port is occupied for spreader integration.

    • A “Null” Modem adapter must be used when connecting to the secondary port.

    • Use HRN-DB9SI15 if additional length is required.