Skip to main content

v1.0

Major VersionM

by Jason Fox

  1. Giletta integration requires HRN-GILNT connected to the control head.
    • Giletta integration requires HRN-GILNT connected to the control head.

  2. Connect one end of HRN-GILNT to the Giletta Ecostat. The other end connects to the IOX-WRKS primary port.
    • Connect one end of HRN-GILNT to the Giletta Ecostat.

    • The other end connects to the IOX-WRKS primary port.

    • Use HRN-DB9SI15 if additional length is required.

  3. From “Main Menu”, select “Communications” and “Serial Data”.
    • From “Main Menu”, select “Communications” and “Serial Data”.

    • Protocol = CEN

    • Baud =9600

    • COM = 1

    • Ensure the IOX-WRKS has the correct controller configuration loaded before proceeding to verification / simulation mode.

  4. Place the controller in Ground speed simulation, set the rates, and confirm data is being captured.
    • Place the controller in Ground speed simulation, set the rates, and confirm data is being captured.

    • Never leave a controller in simulation mode!

Finish Line

Jason Fox

Member since: 09/14/2023

27 Guides authored

Team

Field Service Specialists Member of Field Service Specialists

8 Members

68 Guides authored