Skip to main content

v2.7

Minor Versionm

by Jason Fox

Introduction

Currently supported use cases:

  • Driver Seatbelt - Tracks whether the driver's seatbelt is Buckled or Unbuckled
  • Power Take-Off (PTO) - Tracks whether auxiliary equipment (e.g., a crane or pump) is Engaged or Disengaged
  • Cargo Door - Tracks whether a cargo door is Open or Closed
  • Generic Digital Input - Records the raw on/off signal without a specific label. This option can be used alongside other use cases.
  1. HRN-XGL06S6 has 4 Inputs labeled I1 - I4.
    • HRN-XGL06S6 has 4 Inputs labeled I1 - I4.

    • You will notice a White wire labeled O1 and Black labeled GND. These are not used at this time.

  2. Using a Digital Multimeter identify wires in the vehicle to connect to for desired telemetry.  Identify a wire that changes state: for example voltage changes when door opens, seatbelt buckles, etc.
    • Using a Digital Multimeter identify wires in the vehicle to connect to for desired telemetry. Identify a wire that changes state: for example voltage changes when door opens, seatbelt buckles, etc.

    • It may be useful to refer to one of the following resources (i.e. ALLDATA™, WireSheet™, Mitchell1 ProDemand™ / eAutoRepair™ or equivalent) to locate the required wire in the vehicle.

    • Connect the desired inputs in the vehicle to the HRN-XGL06S6 wires as needed.

  3. Connect the GPIO harness to the I/O port on the back of your GO Device using the 6 pin Molex connector.
    • Connect the GPIO harness to the I/O port on the back of your GO Device using the 6 pin Molex connector.

    • Plug Harness into GO device.

    • Be sure both clip in place. Due to this clip securing the connection a cable tie is not required.

    • When setting up Data Labelling, you will assign one of the following use cases to each digital input on your device:

    • Cargo Door - Tracks whether a cargo door is Open or Closed

    • Power Take-Off (PTO) - Tracks whether auxiliary equipment (e.g., a crane or pump) is Engaged or Disengaged

    • Driver Seatbelt - Tracks whether the driver's seatbelt is Buckled or Unbuckled

    • Generic Digital Input - Records the raw on/off signal without a specific label. This option can be used alongside other use cases.

    • Each input can only be assigned one use case at a time, except for Generic Digital Input.

    • Ensure the harness is wired into the vehicle and plugged in prior to powering on the GO10 or GO10 Plus device

    • Access MyInstall.

    • Select “New installation”

    • Scan the barcode on your device or manually enter the serial number (starting with "X") to locate your GO10™ or GO10 Plus™.

  4. On the Connected Equipment screen, tap "GPIO Setup" on the device card to open the Data Labelling configuration page.
    • On the Connected Equipment screen, tap "GPIO Setup" on the device card to open the Data Labelling configuration page.

  5. Enable each input used by toggling the switch on. Choose the appropriate use case from the drop down list. Tap continue to complete calibration.
    • Enable each input used by toggling the switch on.

    • Choose the appropriate use case from the drop down list.

    • Tap continue to complete calibration.

    • Inputs can be left unassigned if not connected to anything in the vehicle.

    • IMPORTANT: All inputs must be "off" position before starting. For example seatbelt unbuckled, PTO Off, Cargo Door Closed.

  6. The app will display a loading screen for about 10 seconds while the device prepares for calibration. For inputs requiring calibration (Seatbelt, PTO, Cargo Door), the app guides you through each one individually: Trigger the first state (buckle seatbelt / engage PTO / open door) → follow instructions on the screen.
    • The app will display a loading screen for about 10 seconds while the device prepares for calibration.

    • For inputs requiring calibration (Seatbelt, PTO, Cargo Door), the app guides you through each one individually:

    • Trigger the first state (buckle seatbelt / engage PTO / open door) → follow instructions on the screen.

    • Trigger the opposite state (unbuckle / deactivate / close) → wait for screen confirmation. Click to confirm.

    • NOTE: Each input must be calibrated within 2 minutes or the entire configuration is cancelled — restart from previous step. Back button preserves use case selections.

  7. Once the calibration is complete, you will be returned to the Connected Equipment screen, the current status of each input is displayed:
    • Once the calibration is complete, you will be returned to the Connected Equipment screen, the current status of each input is displayed:

    • Cargo Door: Open or Closed

    • PTO: Engaged or Disengaged

    • Driver Seatbelt: Buckled or Unbuckled

    • Generic Digital Input: 0 (off) or 1 (on)

    • Toggle each physical input to confirm the status updates. Use the refresh button if status does not update immediately.

Finish Line